Airpax Güç Koruması

  • Anasayfa /
  • Airpax Gücü /
  • Airpax Güç Koruması
Önceki Sayfa

Airpax Güç Koruması

Product

Description

Poles

Current & Voltage Rating

Operating Temperature

Approvals*

Page

6600 Series

 

 

  • Sub-miniature bimetal thermostat
  • 8-PIN DIP package configuration
  • Snap-acting trip mechanism increases operational life

SPST

  • 1.0A max at 48VDC 25,000 cycles
  • 1.0A max at 120VAC 30,000 cycles
  • 0.020A max at 5VDC 100,000 cycles (gold)
  • 40°C to 130°C (104°F to 266°F)
  • cЯUus
  • VDE approved

 

33

6700 Series

  • Sub-miniature bimetal thermostat
  • TO-220 package configuration
  • Snap-acting trip mechanism increases operational life
  • VDE approved “P” version

SPST

  • 0.5A max at 48VDC 20,000 cycles
  • 0.001A max at 5VDC 100,000 cycles (gold)
  • 40°C to 130°C (104°F to 266°F)
  • cЯUus
  • VDE (“P” option)

 

37

 

IAR Series

  • 1U (1RU) hydraulic magnetic circuit breaker
  • Low-profile design
  • Auxiliary switch options available for alarm signaling

2

  • 50A max at 80 VDC / 250 VAC
  • 30A max, 120/240VAC

(2 poles)

  • 5000A, 65VDC
  • 5000A, 80VDC
  • 2000A, 250VAC
  • 5000A, 120/240VAC (2 poles)
  • 5000A, 80VDC (2 poles)
  • C-UL recognized
  • UL1077 recognized
  • UL489A listed
  • TUV approved

 

42

SNAPAK®

 

 

  • Compact magnetic-hydraulic circuit protector
  • Aesthetically pleasing for front panel mounting
  • Toggle, rocker, push-pull and push-to-reset actuation options

2

  • 7.5A max at 50 VDC / 250 VAC
  • 30A max at 32 VDC / 120 VAC
  • 25A max at 120/240 VAC (two poles)
  • 20A max at 250 VAC (50/60 Hz, at 500AIC)
  • 20A max at 65 VDC [two poles, at 500AIC]
  • 1000A
  • UL recognized
  • CSA certified
  • TUV approved
  • CE compliant
  • CCC approved

 

54

AP Series

 

 

  • QPL to MIL-PRF-39019
  • Sealed magnetic-hydraulic circuit protection
  • Can withstand 100G shock repeatedly
  • Ideal for use in Class 1, Div. 2 Groups A, B, C & D hazardous locations

3

AP ratings

  • 20A max at

50 VDC/ 240 VAC

 

UP ratings (1 pole only)

  • 20A max at 50 VDC
  • 15A max at 120 VAC
  • 7.5A max at 240 VAC

AP ratings

  • 500A, 50 VDC, 120 VAC
  • 300A, 240 VAC

 

UP ratings

  • 1000A, 50VDC, 240 VAC
  • MIL-PRF-M39019
  • UL recognized (UP type only)
  • FM approved (UP type only)

 

70

IPA Series

 

 

 

  • Compact magnetic-hydraulic circuit protection
  • Quick-connect, screw, PC board mount

terminals

  • Auxiliary switch options
  • Multi-pole options with multi or single handle

4

  • 30A max at 65 VDC / 240 VAC
  • 20A max at 80 VDC (300 AIC)
  • 25A max at 250 VAC, 50/60 Hz
  • 15A max at 250 VAC, 400 Hz
  • 25A max at 65 VDC / 250 VAC, (TUV)
  • 15A max at 250 VAC, 400 Hz (TUV)
  • 1000A
  • UL 489A listed (CPA)
  • UL recognized
  • CUR recognized
  • TUV certified
  • CE compliant
  • CCC approved (pending)

 

82

IAG Series

 

 

 

 

  • IEG versions meet IEC spacing requirements for installation in equipment that must comply with IEC 601 and 950, and VDE 0730, 0804 and 0805
  • Multi-pole options with multi or single handle
  • Auxiliary switch options
  • Mid-trip handle option
  • Snap-in mounting option
  • Dual frequency delay options

6

  • 50A max at 80 VDC
  • 50A max at 240 VAC
  • 30A max at 277 VAC, 50/60 Hz
  • 30A max at 250 VAC, 400 Hz
  • 30A max at 125 VAC, 50/60 Hz
  • 30A max at 120/240 VAC, 50/60 Hz
  • 5000A, 240 VAC, 50/60 Hz
  • 1500A, 250 VAC, 400 Hz
  • 7500A, 80 VDC (IEG)
  • 5000A, 80 VDC (CEG)
  • 2000A, 250 VAC, 50/60 Hz (VDE)
  • 4000A, 80 VDC (VDE)
  • 5000A, 125 VAC, 50/60 Hz (LEG)
  • 5000A, 120/240 VAC, 50/60 Hz (LEG)
  • UL 489 listed (LEG)
  • UL 489A listed (CEG)
  • UL recognized
  • CSA certified
  • VDE available
  • CE compliant
  • CCC approved
  • UL 1500 certified
  • QPL to MIL-PRF-55629

 

 

98

LEGA Series

 

 

 

  • LEGA is a new “low depth” version of our standard IAG series hydraulic magnetic circuit breaker

6

  • 50A max at 80 VDC
  • 50A max at 240 VAC
  • 30A max at 277 VAC, 50/60 Hz
  • 30A max at 250 VAC, 400 Hz
  • 30A max at 125 VAC, 50/60 Hz
  • 30A max at 120/240 VAC, 50/60 Hz
  • 5000A, 240 VAC, 50/60 Hz
  • 1500A, 250 VAC, 400 Hz
  • 7500A, 80 VDC (IEG)
  • 5000A, 80 VDC (CEG)
  • 2000A, 250 VAC, 50/60 Hz (VDE)
  • 4000A, 80 VDC (VDE)
  • 5000A, 125 VAC, 50/60 Hz (LEG)
  • 5000A, 120/240 VAC, 50/60 Hz (LEG)
  • UL 489 listed (LEG)
  • UL 489A listed (CEG)
  • UL recognized
  • CSA certified
  • VDE available
  • CE compliant
  • CCC approved
  • UL 1500 certified
  • QPL to MIL-PRF-55629

 

 

122

LEJ Series

 

 

  • 240 VAC hydraulic magnetic circuit breaker
  • UL489 listed
  • Optional LEJA “low depth” version

2

  • 20A max at 240 VAC
  • 5000A, 240 VAC, 50/60 Hz
  • UL 489
  • TUV certified

 

132

 

Page

Product

Description

Poles

Current & Voltage Rating

Interrupting Capacity

Approvals*

 

146

IAL Series

 

 

  • IEL versions meet IEC spacing requirements for installation in equipment that must comply with IEC 601 and 950 and VDE 0730, 0804 and 0805
  • Multi-pole options with multi or single handle
  • Auxiliary switch options
  • Snap-in mounting option
  • Mid-trip handle option
  • Various actuator options
  • Dual frequency delay options

6 max

  • 100A max at 65 VDC
  • 70A max at 80 VDC
  • 50A max at 250VDC
  • 50A max at 300VDC
  • 70A max at 240 VAC, 50/60 Hz
  • 50A max at 277 VAC, 50/60 Hz
  • 50A max at 277/480 VAC, 50/60 Hz
  • 50A max at 250 VAC, 400 Hz
  • 5000A, 240 VAC, 50/60 Hz
  • 1500A, 250 VAC, 400 Hz
  • 7500A, 80 VDC
  • 2000A, 240 VAC, 50/60 Hz (VDE)
  • 2000A, 415 VAC, 50/60 Hz (VDE)
  • 4000A, 80 VDC (VDE)
  • 1200A, 277/480 VAC, 50/60 Hz
  • 5000A, 250VDC
  • 1000A, 300VDC
  • UL recognized
  • CSA certified
  • VDE approved (IEL)
  • CE compliant (IEL)
  • CCC approved
  • UL 1500 certified
  • QPL to MIL-PRF- 55629

 

146

LEL Series

 

 

  • LEL versions meet IEC spacing requirements for installation in equipment that must comply with IEC 601 and 950 and VDE 0730, 0804 and 0805
  • Multi-pole options with multi or single handle
  • Auxiliary switch options
  • Snap-in mounting option
  • Mid-trip handle option
  • Various actuator options
  • Dual frequency delay options

3 max

  • 100A max at 80 VDC
  • 50A max at 125 VAC, 50/60 Hz
  • 80A max at 120/240 VAC, 50/60 Hz
  • 100A max at 80 VDC (VDE)
  • 50A max at 250 VAC (VDE)
  • 50000A, 80 VDC
  • 5000A, 125 VAC
  • 5000A, 120/240 VAC 50/60 Hz
  • 2000A, 80 VDC
  • 2000A, 250 VAC, 50/60 Hz (VDE)
  • 10000A, 120/240VAC, 50/60 Hz
  • UL 489 listed
  • CSA certified
  • VDE approved
  • CE compliant
  • CCC approved

 

146

LELP Series

 

 

  • Unique, parallel current sensing design
  • Compact size, high current capacity
  • Auxiliary switch options
  • Mid-trip handle option

1 max

  • 125A at 80 VDC†
  • 150A at 80 VDC†
  • 175A at 80 VDC†
  • 200A at 80 VDC†
  • 250A at 80 VDC†
  • 251A to 300A at 80 VDC††

† Two paralleled poles

†† Three paralleled poles

  • 10000A, 80 VDC
  • 50000A, 65 VDC (up to 150 amps)
  • 10000A, 80 VDC (> 150 amps)
  • UL 489 listed
  • UL 489A listed
  • CSA certified

 

174

IELR Series

 

 

  • Meets IEC spacing requirements for installation in equipment that must comply with IEC 601 and 950, and VDE 0730, 0804 and 0805
  • Designed to mount on standard 35mm DIN rails

4 max

  • 70A max at 80 VDC
  • 70A max at 250 VAC, 50/60 Hz
  • 50A max at 80 VDC (VDE)
  • 50A max at 250 VAC, 50/60 Hz (VDE)
  • 30A max at 415 VAC, 50/60 Hz (VDE)
  • 7500A, 80 VDC
  • 5000A, 250 VAC, 50/60 Hz
  • 2000A, 277 VAC, 50/60 Hz
  • 2000A at 250 VAC, 50/60 Hz (VDE)
  • 2000A at 415 VAC, 50/60 Hz (VDE)
  • 4000A at 80 VDC (VDE)
  • UL recognized
  • CSA certified
  • VDE approved (IELR)
  • CE compliant

 

186

209 Series

 

  • Front or back connected terminal styles
  • E-frame style model complies with UL 489
  • 249 Power Selector Breaker system is listed as a branch circuit breaker per UL 489
  • Complies with international requirements
  • 279 complies with UL 489A

6 max

  • 100A max at 160 VDC
  • 125A max at 125 VDC
  • 77A max at 600 VAC
  • 100A max at 347/600 VAC
  • 100A max at 120, 240, 277, 480 VAC
  • 100A max , 125 VDC, 240/415 VAC (VDE)
  • 5000A
  • 10000A
  • 4000A (VDE)
  • UL 489 listed
  • UL 489A listed (279)
  • UL recognized
  • CSA certified
  • VDE approved
  • UL1500 certified
  • CCC approved
  • CE compliant

 

204

JAE Series

 

 

  • F-frame style complies with UL 489
  • Various terminal options for design flexibility
  • Reduced voltage drop through the circuit breaker compared to other protective devices
  • Auxiliary switch options
  • Mid-trip handle options

6 max

UL489

  • 100A to 250A at 160 VDC
  • 100A to 250A at 65 VDC
  • 100A to 250A at 125/250 VDC
  • 100A to 250A at 240 VAC

 

UL489A

  • 275A to 800A at 160 VDC
  • 275A to 1200A at 65 VDC
  • 10000A, 160 VDC
  • 10000A, 125/250 VDC
  • 65000A, 65 VDC
  • 10000A, 240 VAC
  • 18000A, 240 VAC
  • 100000A, 65VDC (UL489A up to 800A)
  • UL 489 listed
  • UL 489A listed
  • UL recognized
  • CSA certified
  • VDE approved
  • CCC approved
  • CE compliant

 

 

220

MDS2 Series

 

 

  • Modular Distribution System provides unprecedented flexibility
  • “Hot Plug” modules allow for equipment expansion without power shutdown
  • Unique alarm conductors simplify signal wiring
  • Modular load terminals available with front or rear access

4 to 24

  • Maximum load bus rating per position is 100 amps, 125VDC
  • See Airpax™ IEL series
  • See Airpax™ IEL series

 

 

 

224

PGFM Series

 

 

  • GFCI sensing module designed to operate in tandem with the LEL series circuit breaker with a shunt voltage trip and auxiliary switch
  • Manufactured by North Shore Safety, Ltd., a leader in innovative safety products
  • Automatic and manual reset configurations
  • Power and fault status indicators
  • Double insulated user interface

3 max

Ground Trip Current

  • 4 to 6 mA

Trip Time, Combined Assembly

  • £ 25 mS

Rated Voltage

  • 120 VAC or 240 VAC, 50/60 Hz

Let-Go Voltage

  • 60% of supply voltage
  • See Airpax™ LEL series
  • UL 943, Class A or UL 1053 Compliant

 

 

Download our PDF for more.